How to exhaust the radiator: Hot topics and operation guides on the Internet in the past 10 days
As winter approaches, the use of radiators has become a hot topic on the Internet recently. Many users reported that the radiator was not hot and noisy, and more than 80% of them were related to gas blockage. The following is a compilation of hot topics related to radiator exhaust in the past 10 days, as well as detailed operation guides.
1. Recent hot search data related to radiator exhaust

| Platform | Hot search keywords | Search volume (10,000) | Hot trends |
|---|---|---|---|
| Baidu | Radiator exhaust method | 42.5 | ↑35% |
| Douyin | Solve the abnormal noise of radiator | 28.7 | ↑58% |
| Reasons why the radiator is not hot | 15.3 | ↑22% | |
| little red book | Radiator exhaust tool | 9.8 | ↑41% |
2. The necessity of exhausting the radiator
Gases will be produced during the operation of the heating system, and these gases will form air blockages in the radiator, resulting in:
1. Heat dissipation efficiency drops by more than 50%
2. Water flow noise affects life
3. May cause system corrosion
4. Increase energy consumption by 20%-30%
3. Detailed exhaust steps
| steps | Operating Instructions | Things to note |
|---|---|---|
| 1. Preparation | Prepare a flat-blade screwdriver, a water container, and a dry towel | Turn off the heating valves in other rooms |
| 2. Position the exhaust valve | Usually in the upper right corner of the radiator, there is a square screw head | Confirm valve type (manual/automatic) |
| 3. Start exhausting | Rotate exhaust valve 45 degrees counterclockwise | Stop immediately when you hear a "hissing" sound |
| 4. Observe drainage | Close the valve after the water flow is stable and bubble-free. | Use a container to catch the drained water |
| 5. System check | Check all radiator temperature changes | Repeat if necessary |
4. Exhaust points of different radiator types
1.cast iron radiator: Exhaust frequency is high, once a month is recommended
2.Steel panel radiator: Equipped with automatic exhaust valve, which needs to be checked regularly.
3.Copper-aluminum composite radiator: The exhaust valve is more precise and needs to be operated gently.
5. Frequently Asked Questions
| question | Reason | solution |
|---|---|---|
| Exhaust valve leaking | Seal aging | Replace exhaust valve or sealing ring |
| Still not hot after exhaust | Insufficient system pressure | Contact the property to supplement the pressure |
| Frequent need for exhaust | There is a leak in the system | Ask a professional to check |
6. Professional advice
1. The best exhaust time: in the morning when the system is just started
2. Recommended exhaust frequency: once a month for central heating and once every two weeks for self-heating
3. In case of complicated situations, it is recommended to contact professional maintenance personnel
4. The newly installed heating system needs to be exhausted multiple times when used for the first time.
Correct exhaust through the above methods can improve the efficiency of the radiator by more than 30% and reduce energy consumption at the same time. With the recent cold wave, users are advised to check the condition of their home radiators in time to ensure a warm winter.