How to adjust the high water pressure of the wall-mounted boiler
Recently, there has been a lot of discussion on the use of wall-hung boilers across the Internet, especially as the winter heating season approaches, and many users have reported that the water pressure of wall-hung boilers is too high. This article will combine the hot topics and user concerns in the past 10 days to provide you with detailed answers on how to adjust the water pressure of wall-mounted boilers and provide structured data reference.
1. Common causes of high water pressure in wall-hung boilers

According to user feedback and maintenance data across the network, excessive water pressure in wall-mounted boilers is usually caused by the following reasons:
| Reason | Proportion | Typical performance |
|---|---|---|
| The water replenishment valve is not closed | 45% | Water pressure continues to rise |
| Expansion tank failure | 30% | Large water pressure fluctuations |
| Excessive temperature causes expansion | 15% | With high temperature alarm |
| other reasons | 10% | Requires professional testing |
2. The dangers of high water pressure
According to recent maintenance case statistics, excessive water pressure may cause the following problems:
| Hazard type | probability of occurrence | possible consequences |
|---|---|---|
| Safety valve drains water | 60% | causing waste of water resources |
| Damaged seal | 25% | causing water leakage |
| shorten service life | 10% | Increased maintenance costs |
| other damages | 5% | Requires professional evaluation |
3. Detailed steps for adjusting water pressure
According to recent popular maintenance videos and expert advice, the correct way to adjust water pressure is as follows:
1.Confirm current water pressure: Observe the pressure gauge. The normal value should be between 1-1.5bar. If it exceeds 2bar, it needs to be adjusted.
2.Close the water replenishment valve: Most of the time, high water pressure is because the fill valve is not fully closed. Locate the refill valve (usually a black knob) and turn it clockwise as far as it will go.
3.Pressure relief operation: If the water pressure is too high, you can relieve the pressure in the following ways:
| Pressure relief method | Applicable situations | Operational points |
|---|---|---|
| Discharge water from radiator | With radiator system | Use the release valve to slowly release water |
| Floor heating manifold drainage | Floor heating system | Be careful when opening the drain valve |
| Safety valve pressure relief | emergency | May cause waste of water resources |
4.Check expansion tank: If high water pressure occurs frequently, you may need to check the expansion tank pressure. The normal pre-charge pressure should be 0.8-1bar.
5.System exhaust: After completing the pressure relief, the system needs to be vented to ensure that no air affects the water pressure display.
4. Answers to recent frequently asked questions from users
Based on the data of the online question and answer platform in the past 10 days, the following high-frequency questions have been compiled:
| question | frequency of occurrence | Professional answers |
|---|---|---|
| Is 3bar water pressure dangerous? | 32% | It is too high and needs to be adjusted immediately |
| Do I need to replenish water after automatic pressure relief? | 25% | Observe the pressure gauge to decide |
| What should I do if the water pressure is frequently high? | 20% | Check expansion tank |
| Can I repair it myself? | 15% | Basic adjustments are possible, but complex problems require professional maintenance. |
| Are the adjustment methods the same for different brands? | 8% | The principle is the same, the details may be different |
5. Suggestions on preventing high water pressure
Based on recent successful experiences reported by users, the following preventive measures are provided:
1.Regular inspection: Observe the pressure gauge once a week, more frequently during the heating season.
2.Hydrate correctly: Pay close attention to the pressure gauge when replenishing water. Stop immediately when it reaches 1.5bar.
3.Pay attention to the temperature: Avoid setting the wall-hung boiler temperature too high to reduce the impact of thermal expansion.
4.Annual maintenance: Including checking the expansion tank pressure, safety valve status, etc.
5.Log changes: Establish a simple pressure record to facilitate the discovery of problem patterns.
6. When does it require professional maintenance?
According to recent maintenance big data, it is recommended to contact professionals in the following situations:
| Situation description | Self-solve success rate | Recommended Action |
|---|---|---|
| Pressure rises quickly after pressure relief | 15% | Possible expansion tank failure |
| accompanied by unusual noise | 20% | The system may have serious problems |
| The pressure gauge display is unstable | 25% | Professional testing is required |
| Safety valve continues to leak water | 10% | Report for repair immediately |
Through the above structured data and detailed answers, I hope it can help you effectively solve the problem of high water pressure in wall-mounted boilers. If you encounter complex situations, it is recommended to contact professional after-sales service in time to ensure the safe operation of the heating system.
check the details
check the details